-
C & M Textiles Inc.
Distance: 3.4 Mi7500 rue Saint-Hubert
H2R 2N6 Montreal -
AQUAVAP
Distance: 7.1 Mi9675 rue Clément
H8R 4B4 Lasalle -
Hamelin Enterprises, a division of Hamelin Group Inc.
Distance: 6.5 Mi150 Industrial Blvd
J4B 2X3 Boucherville -
Foyers Valcourt Inc
Distance: 24.4 Mi1345 rue Jacques-Cartier S RR 181
J3B 6Y8 Saint-jean-sur-richelieu -
Brais Malouin & Associés
Distance: 142.6 Mi144, rue Barr
H4T 1Y4 Saint-laurent
Solar Buildings Research Network
- 1455 boul de Maisonneuve O
- Montreal, Quebec
- H3G 1M8
- Phone: 514.848.2424 x8791
- Website
Website Links
Description
Charron R. and Athienitis A.K., 2006, "Design and Optimization of Net Zero Energy Solar Homes", ASHRAE Transactions, Vol. 112, Pt. 2, pp. 285-295. -A Two Dimensional Model of a Double Façade with Integrated Photovoltaic Panels Charron R. and Athienitis A.K., 2006, "A Two Dimensional Model of a Double Façade with Integrated Photovoltaic Panels" ASME Journal of Solar Energy Engineering, Vol. 128, pp. 160-167. -Optimization of the Performance of Double Façades with Integrated Photovoltaic Panels Charron R. and Athienitis A.K., 2006, "Optimization of the Performance of Double Façades with Integrated Photovoltaic Panels", Solar Energy, Vol. 80, No. 5, pp. 482-491. -Determination of Convective Heat Transfer for Glazing Systems with Between-the-Glass Louvered Shades Collins M., Tasnim S., and Wright J., 2007 "Determination of Convective Heat Transfer for Glazing Systems with Between-the-Glass Louvered Shades", International Journal of Heat and Mass Transfer, accepted for publication. -Calculating Centre-Glass Performance Indices of Windows with a Diathermanous Layer, Collins M., Wright J., 2006, "Calculating Centre-Glass Performance Indices of Windows with a Diathermanous Layer," ASHRAE Transactions, Vol. 112, Pt. 2. pp. 22-29, ASHRAE Crosby Field Award, Best Paper of 2006 -Calculating Performance Indices for Windows with Diathermanous Layers Collins M., Wright J., 2006, "Calculating Performance Indices for Windows with Diathermanous Layers", ASHRAE Transactions, Vol. 112(2), pp. 22-29. -Thermal Resistance of a Window with an Enclosed Venetian Blind: Guarded Heater Plate Measurements, Huang N., Wright J., Collins M., 2006, "Thermal Resistance of a Window with an Enclosed Venetian Blind: Guarded Heater Plate Measurements," ASHRAE Transactions, Vol. 112, Pt. 2. pp. 13-21 -Impact of internal pressure coefficients on wind driven ventilation analysis Karava P., Stathopoulos T. and Athienitis A.K., 2006, "Impact of internal pressure coefficients on wind driven ventilation analysis", International Journal of Ventilation, Vol. 5 (1), pp. 53-66. -Wind-driven Natural Ventilation Analysis Karava P., Stathopoulos T. and Athienitis A.K., 2007, "Wind-driven Natural Ventilation Analysis", Solar Energy, Vol. 81, Issue 1, January 2007, Pages 20-30. -Numerical and Experimental Study of Heat Transfer in a BIPV thermal System Liao L., Athienitis A.K., Candanedo L., Park K.W., Poissant Y. and Collins M., 2007, "Numerical and Experimental Study of Heat Transfer in a BIPV thermal System", Journal of Solar Energy Engineering, Vol. 129, Nov., pp. 423-430. -Islanding Detection Assessment of Multi-Inverter Systems with Active Frequency Drifting Methods Lopes L. and Zhang, Y., January 2008, "Islanding Detection Assessment of Multi-Inverter Systems with Active Frequency Drifting Methods", IEEE Transactions on Power Delivery, Vol. 23, No. 1, pp. 480 - 486. -Performance Assessment of Active Frequency Drifting Islanding Detection Methods Lopes L. and Sun H. 2006, "Performance Assessment of Active Frequency Drifting Islanding Detection Methods", IEEE Transactions on Energy Conversion, Vol. 21, No. 1, March, pp.